Logo

Publikacije (45085)

Nazad
A. Djordjevic-Dikic, M. Ostojić, B. Beleslin, I. Nedeljkovic, J. Stepanović, S. Stojkovic, Z. Petrasinovic, M. Nedeljković et al.

ObjectiveThe aim of this study was to evaluate the diagnostic potential of low-dose adenosine stress echocardiography in detection of myocardial viability.BackgroundVasodilation through low dose dipyridamole infusion may recruit contractile reserve by increasing coronary flow or by increasing levels of endogenous adenosine.MethodsForty-three patients with resting dyssynergy, due to previous myocardial infarction, underwent low-dose adenosine (80, 100, 110 mcg/kg/min in 3 minutes intervals) echocardiography test. Gold standard for myocardial viability was improvement in systolic thickening of dyssinergic segments of ≥ 1 grade at follow-up. Coronary angiography was done in 41 pts. Twenty-seven patients were revascularized and 16 were medically treated. Echocardiographic follow up data (12 ± 2 months) were available in 24 revascularized patients.ResultsWall motion score index improved from rest 1.55 ± 0.30 to 1.33 ± 0.26 at low-dose adenosine (p < 0.001). Of the 257 segments with baseline dyssynergy, adenosine echocardiography identified 122 segments as positive for viability, and 135 as necrotic since no improvement of systolic thickening was observed. Follow-up wall motion score index was 1.31 ± 0.30 (p < 0.001 vs. rest). The sensitivity of adenosine echo test for identification of viable segments was 87%, while specificity was 95%, and diagnostic accuracy 90%. Positive and negative predictive values were 97% and 80%, respectively.ConclusionLow-dose adenosine stress echocardiography test has high diagnostic potential for detection of myocardial viability in the group of patients with left ventricle dysfunction due to previous myocardial infarction. Low dose adenosine stress echocardiography may be adequate alternative to low-dose dobutamine test for evaluation of myocardial viability.

J. McQuiston, R. Gibbons, R. Velić, W. Nicholson, L. Castrodale, S. H. Wainright, T. Vanniewenhoven, E. Morgan et al.

Z. Mujagic, H. Mujagić

BACKGROUND AND PURPOSE Carcinoembryonic antigen (CEA) is used as a tumour marker in breast cancer (BC). In order to assess diagnostic value of CEA in BC we examined its serum levels and frequencies of its increase in breast cancer patients (BCP), and compared them to those in controls. We also determined CEA in patients with metastatic and non-metastatic BC, and calculated sensitivity and specificity of CEA in BC. PATIENTS AND METHODS The main experimental group consisted of 47 female patients with histologically proved diagnosis of BC. There were two control groups: clinically healthy women, and female patients with other locations of cancer. Circulating levels of CEA were measured by means of immunoradiometric assay. Results were processed by means of t-test and two-way analysis of variance. RESULTS Circulating levels of CEA, before treatment in BCP, were significantly higher (p<0.0001) than in healthy women, and in patients with other cancers (p<0.007), while serum CEA in other cancer patients was significantly higher (p<0.01) than in healthy control. There was a difference between frequencies of CEA increase in BCP and healthy women, while such a difference did not exist between BCP and other cancer patients. The circulating levels of CEA in metastatic BCP were significantly higher (p<0.03) in comparison to non-metastatic patients. Sensitivity and specificity of CEA in BCP was 65.0%, and 57.1%, respectively. CONCLUSIONS CEA does not have high tumour specificity for BC, since its circulating levels as well as frequencies of its increase may be elevated in patients with other types and locations of cancer, different from breast cancer. CEA can be detected in the serum of majority of patients with metastatic BC. CEA may be used as prognostic tumour marker in advanced BC.

Defining exact position of weak anatomic function which is find in a base of neurological and psychiatric disorder is just became the subject of intensive research interest. For this purposes it is important to implement structural and functional MRI techniques, also for further lightening and seeing subject of this work, more concretely connected to PTSD. Therefore, exactly MRI gives most sensitive volumetric measuring of hippocampal formation and amygdaloidal complex. The goal of this work was to research asymmetry of hippocampal formation and amygdaloidal complex to the PTSD patients. Results showed that at the axial slice length of hippocampal formation on the left and right side of all patients are significantly asymmetric. At the sagittal slice from the left side of hippocampal formation is in many cases longer than right about 50 %. At the coronal slice, there are no significant differences toward patient proportion according to symm./asymm. of the hippocampal formation width at the right and left side. Difference in volume average of hippocampal formation between right and left side for axial and coronal slice is not statistically significant, but it is significant for sagittal slice. In about amygdaloidal complex patients with PTSD toward symm./asymm. Amygdaloidal complex at the right and left side of axial and sagittal slice in all three measurement shows asymmetry, what is especially shown at sagittal slice. Difference in average length of amygdaloidal complex at the right and left side is not statistically significant for no one slice. Therefore, results of a new research that are used MRI, showed smaller hippocampal level at PTSD (researched by Van der Kolka 1996, Pitman 1996, Bremner et al., 1995.). Application of MRI technique in research of asymmetry of hippocampal formation and amygdaloidal complex, which we used in our research, we recommend as a template for future researches in a sense of lightening anatomic function that is a base of neuropsychiatric disorders.

Medical devices and medical disposables contribute significantly to the quality and effectiveness of the health care system. It is necessary to commit scientifically sound regulatory environment that will provide consumers with the best medical care. This includes continued services to small manufacturers, readily available guidance on FDA requirements, predictable and reasonable response times on applications for marketing, and equitable enforcement. But in the public interest, this commitment to the industry must be coupled with a reciprocal commitment: that medical device firms will meet high standards in the design, manufacture, and evaluation of their products. The protections afforded our consumer, and the benefits provided the medical device industry, cannot be underestimated.

E. Suljević, Muhamed Fazlić, J. Ćorić, Jozo Corić i Emina Kiseljaković

Research on the parameters of full blood count and differential white blood count is included in the program of all medical laboratories of primary, secondary and tertiary health care levels. Today, all haematological tests are exclusively performed on the haematology analyzers. Automation of haematology laboratories is a result of the huge requires for haematological test performing, timely issuing of the haematological findings, and possibility of the usage of modern techniques. This work is an evaluation of laser haematology analyzer Cell-Dyn 3700 SL. It investigates the reliability of test results throughout the following parameters: precision, accuracy, sensitivity and specificity of determination methods. It also explores the influence of sample transferring and correlation with haematology analyzer MAXM Retti. Haematology parameters that have been investigated are: white blood cell (WBC), neutrophils (NEU), lymphocytes (LXM), monocytes (MONO), eosinophils (EOS), basophils (BASO), red blood cells (RBC), haemoglobin (HGB), haematocrit (HCT), mean corpuscular volume (MCV), mean corpuscular haemoglobin (MCHC) red cell distribution width (RDW), platelet (PLT), mean platelet volume (MPV), plateletocrit (PCT), and platelet distribution width (PDW). The results confirms that precision of analyzer fulfils the reproducibility of testing parameters: WBC, RBC, HGB, MCV, MCH, MCHC, and PLT. Correlation coefficient values (r) gained throughout the statistical analysis, that is linear regression results obtained throughout the comparison of two analyzers are adequate except for MCHC (r = 0.64), what is in accordance with literature data. Accuracy is tested by haematology analyzer method and microscopic differentiating method. Correlation coefficient results for granulocytes, lymphocytes and monocytes point the accuracy of methods. Sensitivity and specificity parameters fulfil the analytical criteria. It is confirmed that haematology analyzer Cell-Dyn 3700 SL is reliable for the determination of full blood count in everyday work. Analyzer and its program for differential white blood count can be used for the research and separation of normal and pathological blood counts with addition of microscopic methods confirming distribution or morphologic changes of leukocytes.

S. Čavaljuga, I. Licanin, N. Mulabegović, D. Potkonjak

Posttraumatic stress disorder (PTSD) is a psychiatric disorder characterised by an acute emotional response to a traumatic event or situation involving severe environmental stress (natural disasters, wars, epidemics, rape, assaults, physical torture, catastrophic illness or accident), which may be identified in cognitive, affective or sensory motor activities. The objective was to perform a pilot clinical trial designed to compare the effects of older (tricyclic) and newer "second-generation" (selective inhibitors of serotonin uptake) antidepressants in the treatment of PTSD. A total of 20 hospitalised chronic military combat Bosnian veterans with PTSD symptoms were randomly assigned into two groups of 10 patients each. One group was treated with amitriptyline hydrochloride (AMYZOL) 75 mg/day as a representative of older antidepressants and the other with fluoxetine hydrochloride 60 mg/day (OXETIN) as a representative of newer antidepressants. Those drugs were administered by mouth two or three times-a-day in equally divided doses for at least 8 weeks. Favourable response was achieved in 70% of patients treated with amitriptyline hydrochloride and 60% of patients treated with fluoxetine hydrochloride. Amitriptyline hydrochloride was more effective in the treatment of acute PTSD symptoms (emotional numbing, startle reaction, nightmares, flashbacks, intrusive thoughts, vulnerability, poor impulse control or irritability and explosiveness). Fluoxetine hydrochloride showed a greater efficacy in the treatment of chronic PTSD symptoms (avoidance and numbing symptoms, hyperarousal, nightmares and a feeling of guilt).

Nema pronađenih rezultata, molimo da izmjenite uslove pretrage i pokušate ponovo!

Pretplatite se na novosti o BH Akademskom Imeniku

Ova stranica koristi kolačiće da bi vam pružila najbolje iskustvo

Saznaj više