Logo
User Name

Nedim Pervan

Društvene mreže:

Elmedin Mešić, Nedim Pervan, Adil Muminović, Edvin Rahman, Bakir Muminović

The primary objective of external fixation is to stabilize bone fractures, with the mechanical characteristics of the fixation system playing a critical role in shaping the biomechanical environment of the fracture and, consequently, the healing process. This study presents an experimental investigation of the stability of eight unilateral external fixation configurations applied to an open tibial fracture. The stiffness of each configuration was evaluated under axial compression, anterior–posterior (AP) bending, medial–lateral (ML) bending, and torsional loading. In addition, the effects of structural parameters—such as the number of half-pins, planarity of the configuration, and interfragmentary distance—on fixator stiffness and generated stresses were examined. The results revealed a linear relationship between applied load and both bone segment displacement and principal stresses. Biomechanical tests demonstrated that biplanar configurations provide sufficient stability for open tibial fractures, while simultaneously offering an optimal structural design for the fixation system. Moreover, the number of half-pins was identified as a statistically significant factor influencing configuration stiffness under axial loading and torsion, with biplanar configurations proving particularly effective in torsional scenarios. However, in AP and ML bending tests, neither configuration type nor any individual parameter produced statistically significant differences in bending stiffness. Interestingly, interfragmentary distance did not exert a statistically significant effect on configuration stiffness under any loading condition. Furthermore, neither configuration type nor the analyzed parameters had a notable influence on the principal stresses measured at the control points.

Background: The study investigates newly developed composite materials with advanced filler technology and modified resin matrices, designed to enhance esthetic quality, clinical efficiency, and mechanical properties. This study evaluated the effect of two light-curing protocols—a conventional low-voltage (LV) protocol (10 s at 1200 mW/cm2) and a high-voltage (HV) protocol (3 s at 3000 mW/cm2)—on the microhardness (MH), bottom/top MH ratio, and the correlation between filler content (wt%, vol%) and MH of bulk-fill resin-based composites (RBCs). Four RBCs were tested: Tetric PlusFill (TPF), Tetric Plus Flow(TPFW), Tetric PowerFill (PFL), and Tetric PowerFlow (PFW). Materials and Methods: Samples were fabricated in the laboratory using specially designed cylindrical molds (diameter = 8 mm, height = 4 mm). Initial MH was measured on the top and bottom surfaces of composite specimens 24 h after light curing using a digital microhardness tester (QNESS 60 M EVO, ATM Qness GmbH, Mammelzen, Germany). The correlation between the filler content (wt%, vol%) and the MH of the RBCs was tested. For the calculation of depth-dependent curing effectiveness, the bottom/top ratio for initial MH was used. Conclusions: The MH of bulk-fill RBCs was found to be influenced by both material composition and the applied light-curing protocol. An increase in filler content resulted in higher MH values under both protocols, with the filler volume fraction exhibiting a stronger correlation than the weight fraction. While both flowable and sculptable Tetric Plus composites exhibited higher MH values under the HV protocol, Tetric Power composites demonstrated greater initial hardness under LV protocol. The flowable composite PFW showed the most pronounced reduction in MH under HV curing. The bottom/top MH ratio exceeded 80% in all tested materials, confirming adequate polymerization throughout the composite layers.

Elmedin Mešić, Adela Zenkić, Adis J. Muminović, Nedim Pervan

Structural analysis of two designs of total hip endoprosthesis was conducted with an emphasis on verifying stress conditions and displacement fields on the components and femur under loads typical for human gait. CAD (Computer Aided Design) models of a conventional endoprosthesis (Endoprosthesis 1) and a more modern solution (Endoprosthesis 2) were created using the CATIA (Computer Aided Three-dimensional Interactive Application) CAD/CAE (Computer Aided Engineering) system, based on which corresponding FEM (Finite Element Method) models were formed. By comparing the obtained results, it was found that a more uniform stress-strain pattern occurs on most components of Endoprosthesis 2 compared to Endoprosthesis 1. Additionally, the analysis of von Mises stresses and displacements at characteristic points of the femur showed a balanced distribution of stress and displacement. However, higher contact stresses between the stem and femur occur with Endoprosthesis 2, reducing the possibility of stress shielding due to the specifics of its design.

In this paper, an assessment of the impact of the electrification of the vehicle fleet in Bosnia and Herzegovina on the total electrical energy consumption is made, for different scenarios of increasing the number of electric vehicles. Based on a statistical analysis of the structure and number of vehicles in Bosnia and Herzegovina in the period from 2010 to 2024, an estimate of the total number of passenger cars, as well as the number of electric vehicles for the period up to 2050, is made. It is estimated that in 2050 the number of electric passenger cars will be around 300,000. For one representative electric passenger car, averaged annual electrical energy consumption is calculated. Based on the calculation and for the estimated number of electric vehicles in use, the total annual consumption of electrical energy for the segment of passenger cars is defined, for different scenarios of increasing the number of electric vehicles. Following the estimated increase in the number of passenger electric cars, an exponential increase in electrical energy consumption is estimated, reaching the annual amount of 635 GWh in 2050, which is 10 times higher than the total electrical energy consumption of the transport sector in 2024. In this way, for the period up to 2050, the additional amount of electrical energy that the electrical power grid should provide, due to the electrification of the vehicle fleet, is estimated.

An assessment of different materials for additive manufacturing (AM) of polymer gears is presented in this research. Experimental testing is carried out for three different materials. Two materials are selected as the most common materials used for gears made by additive manufacturing. These materials are nylon and polycarbonate (PC). The third material is IGUS i180, which is a tribological material specially developed for additive manufacturing of parts with demands for high resistance properties such as resistance to friction, wear, and high temperatures which are essential for the long service life of gears. Gears are experimentally tested to determine service life in the form of operating cycles until failure. In addition, the gear temperature is monitored during the experimental testing. Using the value of maximum temperature at the moment of total gear failure at a specific load level enables the categorization of failure type. Different types of gear failures are categorized and presented. Taking into consideration failure type and the service life in the form of operating cycles, the applicability of analyzed materials for specific applications concerning load, speed, and thermal conditions is presented and discussed at the end of the paper. The main goal of this research was to test IGUS i180 material and compare its mechanical and thermal properties with other commonly used materials for gears manufactured by AM, such as nylon (PA6/66) and polycarbonate (PC). IGUS i180 material showed inferior properties concerning gear design in the case of high loads. This research showed that PA6/66 material is still the best solution for polymer gears production using AM, but the applicability of this material, due to temperature constraints, is still quite limited.

Damir Duratbegović, Nedim Pervan, Selma Jakupović, S. Kobašlija

(1) Background: This study investigates the effects of curing light intensity, exposure time, and distance on the Vickers microhardness (VMH), hardness bottom-to-top ratio (HR), and temperature rise (TR) of conventional dental resin-based composite (RBC). (2) Materials and Methods: Specimens of one conventional RBC (Tetric EvoCeram, Ivoclar Vivadent) were cured with 12 different curing protocols (CPs), created with three different light intensities (Quartz Tungsten Halogen 300 mW/cm2, LED 650 mW/cm2, LED 1100 mW/cm2), two exposure times (20 and 40 s), and two distances of curing tip (0 and 8 mm). The VMH of top (VMH-T) and bottom (VMH-B) surfaces was measured. The hardness bottom-to-top ratio (HR) was calculated from VMH-B and VMH-T. The HR below 80% was rated as inadequate polymerization. The TR at the depth of 2 mm within the RBC was measured using a K-type thermocouple. Data were analyzed using Levene’s test and the multivariate analysis of variance (MANOVA). The level of significance was set at p < 0.05. (3) Results: Exposure time and distance significantly influenced VMH-B and HR. Increased distance significantly reduced VMH-B, HR, and TR. CPs 300 mW/cm2/8 mm/20 s and 650 mW/cm2/8 mm/20 s produced inadequate polymerization (HR < 80%). Prolonged exposure time produced higher values of VMH-B and HR. The TR was significantly influenced by light intensity and distance. (4) Conclusions: Suboptimal light intensity (<800 mW/cm2) can produce inadequate polymerization at the lower side of the composite layer when used from a distance. Prolonged irradiation can improve the polymerization to a certain extent. Clinicians are advised to monitor the intensity of the LCUs in order to optimize the photopolymerization process. Caution is required when polymerizing with high-intensity curing light in direct contact with the RBC with longer exposure times than recommended.

As surface wear is one of the major failure mechanisms in many applications that include polymer gears, lifetime prediction of polymer gears often requires time-consuming and expensive experimental testing. This study introduces a contact mechanics model for the surface wear prediction of polymer gears. The developed model, which is based on an iterative numerical procedure, employs a boundary element method (BEM) in conjunction with Archard’s wear equation to predict wear depth on contacting tooth surfaces. The wear coefficients, necessary for the model development, have been determined experimentally for Polyoxymethylene (POM) and Polyvinylidene fluoride (PVDF) polymer gear samples by employing an abrasive wear model by the VDI 2736 guidelines for polymer gear design. To fully describe the complex changes in contact topography as the gears wear, the prediction model employs Winkler’s surface formulation used for the computation of the contact pressure distribution and Weber’s model for the computation of wear-induced changes in stiffness components as well as the alterations in the load-sharing factors with corresponding effects on the normal load distribution. The developed contact mechanics model has been validated through experimental testing of steel/polymer engagements after an arbitrary number of load cycles. Based on the comparison of the simulated and experimental results, it can be concluded that the developed model can be used to predict the surface wear of polymer gears, therefore reducing the need to perform experimental testing. One of the major benefits of the developed model is the possibility of assessing and visualizing the numerous contact parameters that simultaneously affect the wear behavior, which can be used to determine the wear patterns of contacting tooth surfaces after a certain number of load cycles, i.e., different lifetime stages of polymer gears.

With the ever-increasing number of polymer materials and the current number of commercially available materials, the polymer gear design process, regarding the wear lifetime predictions, is a difficult task given that there are very limited data on wear coefficients that can be deployed to evaluate the wear behavior of polymer gears. This study focuses on the classic steel/polymer engagements that result in a wear-induced failure of polymer gears and proposes a simple methodology based on the employment of optical methods that can be used to assess the necessary wear coefficient. Polymer gear testing, performed on an open-loop test rig, along with VDI 2736 guidelines for polymer gear design, serves as a starting point for the detailed analysis of the wear process putting into service a digital microscope that leads to the evaluation of the wear coefficient. The same wear coefficient, as presented within the scope of this study, can be implemented in a rather simple wear prediction model, based on Archard’s wear formulation. The developed model is established on the iterative numerical procedure that accounts for the changes in tooth flank geometry due to wear and investigates the surface wear impact on the contact pressure distribution to completely describe the behavior of polymer gears in different stages of their lifetime. Although a simple one, the developed wear prediction model is sufficient for most engineering applications, as the model prediction and experimental data agree well with each other, and can be utilized to reduce the need to perform time-consuming testing.

Product design and manufacturing leverage 3D scanning for various applications. This study aims to investigate the effectiveness of 3D scanning in furniture production by surveying the literature and showcasing four real-world case studies. The literature review reveals that 3D data acquired from real-world objects have applications in research, rapid prototyping, restoration, and preservation of antique furniture, optimizing CNC machining processes, and measuring furniture components for quality control. The case study descriptions demonstrated the circumstances, rationale, and methodology for 3D scanning. All the case studies analyzed stem from the collaboration between the Laboratory for Product Development and Design at the Faculty of Mechanical Engineering at the University of Sarajevo and various furniture production enterprises from Bosnia and Herzegovina. The conclusions highlight that 3D scanning in the furniture sector is advantageous for developing computer-aided design models from early-stage design prototypes, validating the dimensional accuracy of manufactured components by comparing with CAD models, safeguarding and reconstructing vintage furniture, and remanufacturing formerly produced goods that lack complete technical records (reverse engineering).

The current paper investigates the effects of geometric design parameters on the fatigue failure of the drive axle housing using the Finite Element Method (FEM). The study examines the effects of various factors on the fatigue life of the drive axle housing, such as axle housing wall thickness, housing cross-sectional rounding radius, and rounding radius of the central part of the housing. Based on the known material properties and dynamic loads, a CAD/FEM model of the drive axle housing was developed, and a structural analysis was carried out. Based on the results of the structural analysis, critical places on the housing were determined, and fatigue analysis and lifetime prediction were performed. Through a series of simulations, the study reveals that increasing housing wall thickness can significantly improve fatigue performance. Similarly, increasing the rounding radius at the housing cross-section, as well as the rounding radius at the central part of the housing can also lead to improved fatigue performance. However, the effect of increasing the value of these two radii is not as significant as the effect of the wall thickness. These findings give useful information regarding the design and manufacture of drive axle housings for vehicles, intending to reduce the likelihood of fatigue failure.

...
...
...