Logo

Publikacije (20)

Nazad

AIM To investigate effects of post-sampling analysis time, a type of blood samples and collection tubes on blood gas testing. METHODS This study included 100 patients at the Clinic for Pulmonary Diseases, Clinical Centre Sarajevo. The partial pressure of oxygen (pO2) and carbon dioxide (pCO2), and the oxygen saturation level of hemoglobin (sO2) were analyzed in the arterial blood samples (ABS) and capillary blood samples (CBS) by a potentiometric method using a blood gas analyzer ABL 555 (Radiometer, Copenhagen, Denmark). Paired measurements of ABS were performed within 15 minutes and after 60 minutes from sampling and compared. The results of CBS obtained within 15 minutes were compared with matching ABS results, as well as the results obtained from CBS within 15 minutes taken into glass and plastic tubes. RESULTS pO2 and sO2 values were significantly lower after 60 minutes compared to those within 15 minutes in ABS (9.20±1.89 vs. 9.51±1.95 and 91.25±5.03 vs. 92.40±4.5; p<0.01, respectively). Values of pO2 and sO2 in CBS were significantly lower than values obtained in ABS (8.92±2.07 vs. 9.51±1.95 and 91.25±4.86 vs. 92.40±4.50; p<0.01, respectively). Obtained pO2 and sO2 values in CBS in the plastic tubes were higher than those in the glass tubes (8.50±1.98 vs. 7.89±2.0 and 89.66±11.04 vs. 88.23±11.22, p<0.01 respectively). pCO2 blood values were not influenced significantly (p>0.05). CONCLUSION The length of post-sampling analysis time, a type of blood samples and collection tubes have significant impact on blood oxygen parameters. Analysis within 15 minutes after blood sampling is considered as appropriate.

ABSTRACT Introduction: Central Venous Catheters (CVC) are essential in everyday medical practice, especially in treating patients in intensive care units (ICU). The application of these catheters is accompanied with the risk of complications, such as the complications caused during the CVC insertion, infections at the location of the insertion, and complications during the use of the catheter, sepsis and other metastatic infections. Patients and methods: This study is a retrospective-prospective and it was implemented in the period 1st January 2011- 31st December 2012. It included 108 examinees with CVC placed for more than 7 days. Results: The most common complications occurring in more than 2 attempts of CVC applications are: hearth arrhythmias in both groups in 12 cases, 7 in multi-lumen (12.72%) and 5 in mono-lumen ones (9.43%). Artery puncture occurs in both groups in 7 cases, 5 in multi-lumen (9.09%) and 2 in mono-lumen ones (3.77%). Hematoma occurred in both groups in 4 cases, 3 in multi-lumen CVCs (5.45%) and 1 in mono-lumen ones (1.88%). The most common complication in multi-lumen catheters was heart arrhythmia, in 20 cases (36.37%). The most common complications in mono-lumen CVCs was hearth arrhythmias, in 20 cases as extrasystoles and they were registered in 16 catheter insertions (30.18%). Out of total number of catheters of both groups, out of 108 catheters the complications during insertion occurred in 49 catheters (45.40%). The most common complications in both groups were heart arrhythmias, artery punctures and hematomas at the place of catheter insertion.

Nema pronađenih rezultata, molimo da izmjenite uslove pretrage i pokušate ponovo!

Pretplatite se na novosti o BH Akademskom Imeniku

Ova stranica koristi kolačiće da bi vam pružila najbolje iskustvo

Saznaj više