Logo
Nazad
David Tudiwer, A. Korjenic
3 15. 11. 2017.

The Effect of Living Wall Systems on the Heat Resistance Value of the Façade

This paper shows how facade greening effects the heat resistance value on an old building. The facades of the building are made out of bricks. Two greened facades with different living wall systems have been researched and measured for one heating season. At the same time two not greened parts of the facade were measured. So far there does not exist any general method, how to calculate the U-value or particular heat resistance values of the greened facades. The method which is developed within this research-paper makes the comparison between the greened part of the facade and the not greened part possible. It turned out that there is a difference of the thermal resistance between greened and not greened parts of the facades in winter. The improvement by the greening will be discussed within this paper.


Pretplatite se na novosti o BH Akademskom Imeniku

Ova stranica koristi kolačiće da bi vam pružila najbolje iskustvo